Diagnostics
From requisition to signed report without a single retype.
Orders arrive from OPD and wards, samples are tracked by barcode, results are validated in two steps and the report is a deterministic PDF the patient can also see in the portal.
Who it is for
Hospital labs, pathology chains and diagnostic centres.
The screen
The real thing, on sample data.
A working replica of this module's screen. Click anything; every row is fictional.
What it does
Laboratory information system, in detail.
01
Lab masters
Tests, panels, reference ranges by age and sex, units and methods.
02
Requisition & samples
Collection lists, barcode labels, rejection reasons and TAT tracking.
03
Validation & publish
Technician entry, pathologist validation, amendments with history.
04
Critical results
Abnormal flags and a closed-loop critical-result notification to the treating doctor.
05
Dispatch & portal
Report-ready boards, email dispatch and portal access for patients.
06
PC-PNDT Form F
The statutory form blocks report rendering until it is complete.
What a laboratory information system does in an Indian hospital
Orders arrive from the OPD, the wards and walk-ins. Each sample is labelled with a barcode, tracked from collection to result, and rejected with a reason when it has to be. Results are entered by the technician and validated by the pathologist in a second step, amendments keep their history, and the report is a deterministic PDF that looks the same every time it is printed.
Reference ranges are set by age and sex, turnaround time is tracked per test, and the report-ready board shows the front desk what can be handed over.
Critical results that close the loop
A critical value is only useful if the treating doctor sees it. Curanto raises a critical-result alert to the doctor and keeps it open until someone acknowledges it, so an unread potassium of 6.8 does not sit in a queue overnight.
Quality control and the statutory forms
Internal quality control runs are recorded against each analyte and plotted on Levey-Jennings charts, so drift shows before it reaches a patient's report. For ultrasound and other PC-PNDT work, the report cannot be rendered until Form F is complete.
- Tests, panels, units and methods in one master
- Barcode sample tracking with rejection reasons
- Two-step validation with amendment history
- Internal QC with Levey-Jennings charts
- Email dispatch and a patient portal for reports
For standalone diagnostic centres
Curanto also runs a standalone lab or pathology chain: walk-in registration, billing for diagnostic services, samples received from other centres, email dispatch and the patient portal, on the Clinic Team plan or above.
Questions
Laboratory information system: common questions.
Does Curanto connect to lab analysers?
Not yet. Analyser interfaces are on the roadmap; today results are entered by the lab or imported, then validated in two steps.
Is it suitable for an NABL-accredited lab?
It keeps what assessors look at: reference ranges by age and sex, validation and amendment history, turnaround times and QC charts. Accreditation itself is a process your lab runs.
Can patients download their reports?
Yes. Published reports can be emailed and are available in the patient portal.
How are critical results handled?
A critical value raises an alert to the treating doctor that stays open until it is acknowledged, and the acknowledgement is recorded.
Works with
The modules it hands off to.
See Curanto on your own workflows.
A 30-minute walkthrough with a founder, on a sandbox loaded with a hospital like yours. No card, no self-serve signup, no pressure.
Or write to sales@curanto.in. We reply within one working day, Mon to Sat, 10:00 to 19:00 IST.